A broad SIMATIC s7 200 modules range are offered by means of SIEMENS for maximum huge ranging software. to be had CPU types and expansion modules permit universal automation concept with 10 to 248 input /outputs. the products of s7- 200 own family which are optimally matched to every different additionally make it smooth to exchange and make bigger the automation answer inside the future.
![]() |
Application arease.g.: The CPUs are each presented in five different variations, with various connection and manage voltages. the PPI interface constructed into all CPUs enables factor-to-factor connections to pg/pc, SIMATIC op, expanded SIMATIC s7-200 and user-described cease gadgets (printer, bar code reader). with pg/pc or op as master, a most of 31 SIMATIC s7-200 devices may be connected collectively. if additional inputs/outputs are required, a spread of various expansion modules is available. those are actually connected to the CPU through a connector. |
Counter | 4 (30 kHz)/2 (200 kHz) |
Supported protocols | PPI and MPI slave or Freeport |
Clock | Real-time clock |
Interfaces | 2 x RS 485 |
Program memory | 12/16 Kb |
Analogue potentiometer | 2 |
Data storage | 10 Kb |
No. of extension modules | Max 7 |
Protection type | IP20 |
Type | CPU 224 XP DC/DC/DC |
Manufacturer part No. | 6ES7214-2AD23-0XB0 |
T | 62 mm |
Height | 80 mm |
Width | 140 mm |
Display | No |
No. of digital inputs (max.) | 14 |
Operating voltage | 24 Vdc |
No. of transistor outputs (max.) | 10 |
No. of inputs (max.) | 14 |
Category | SPS controller |
No. of outputs (max.) | 1 |
Attribute | EM 277 PROFIBUS-DP Module | CP 243-2 AS Interface Module |
Interface | 1 x RS 485 | AS Interface |
Supported | MPI Slave/PROFIBUS-DP | AS-i |
protocols | ||
Transmission speeds | 9,600 baud → 12 MBAUD self-negotiating | Max. 5 ms cycle time for 31 slaves |
Connectable | Text Display TD | Max. 31 AS Interface Slaves |
subscribers | 200 from V2.0 | |
Operator Panels | ||
Touch Panels PG / PC with MPI I interface CPU | ||
S7-300/400 PROFIBUS-DP Master or Slaves | ||
Status indicators | CPU Error, Power, DP Error, DX Mode | Status indicators for slaves, Error indicators |
Station address | Can be set at module (0 → 99) | Not necessary |
Galvanic | 500 V AC | No |
isolation | ||
Max. Cable lengths (without repeater) | 1200 m (at 93.75 KBAUD) | 100 m |
Dimensions (WXHXD) | 71 x 80 x 62 | 71.2 x 80 x 62 |
Note: Please send your resume & call placement for the same.
If you have any querry for related Products ... We are available
Contact us